Product Data Sheet
November 2014
00813-0100-4697, Rev NA
Innovative temperature measurement for high density applications that provide installation and
operational savings
Independently configurable inputs that support RTD, thermocouple, ohm, mV, 0-10 volt, and 4–20 mA
signals
Enclosure options and intrinsically safe design allows for installation close to any process, including
hazardous areas
WirelessHART
®
capabilities extends the full benefits of PlantWeb
®
to previously inaccessible locations
Industry first Measurement Validation diagnostic can identify a variety of process concerns including
sensor degradation, sensor wiring connectivity, high vibration (affecting the measurement), and
abnormal process variations.
Rosemount 848T High Density Temperature
Measurement Family
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Measurement Family

Product Data SheetNovember 201400813-0100-4697, Rev NA Innovative temperature measurement for high density applications that provide installation and

Seite 2 - Contents

10Rosemount 848T FamilyNovember 2014www.rosemount.comAccuracy Table 2. Input Options/AccuracySensor optionInput rangesAccuracy over range(s)Sensor re

Seite 3

11Rosemount 848T FamilyNovember 2014www.rosemount.comDifferential configuration notesDifferential capability exists between any two sensor types.For a

Seite 4

12Rosemount 848T FamilyNovember 2014www.rosemount.comAmbient temperature effectTransmitters may be installed in locations where the ambient temperatur

Seite 5 - Transmitter

13Rosemount 848T FamilyNovember 2014www.rosemount.comAmbient temperature notesExamples When using a Pt 100 (α = 0.00385) sensor input at 30 °C ambient

Seite 6

14Rosemount 848T FamilyNovember 2014www.rosemount.comProduct CertificationsEuropean Directive InformationA copy of the EC Declaration of Conformity ca

Seite 7

15Rosemount 848T FamilyNovember 2014www.rosemount.comMarkings: Explosionproof for Class I, Division 1, Groups B, C, and D; T4(-40 °C ≤ Ta ≤+40 °C) w

Seite 8

16Rosemount 848T FamilyNovember 2014www.rosemount.comSpecial Conditions for Safe Use (X):1. Provision must be made, external to the apparatus, to ensu

Seite 9 - Function blocks

17Rosemount 848T FamilyNovember 2014www.rosemount.comNC ATEX Type n (without enclosure)Certificate: IECEx BAS 09.0031UStandards: IEC 60079-0:2004, IEC

Seite 10 - Accuracy

18Rosemount 848T FamilyNovember 2014www.rosemount.com2. This apparatus is not capable of withstanding the 500 V rms insulation test required by Clause

Seite 11 - Rosemount 848T Family

19Rosemount 848T FamilyNovember 2014www.rosemount.comCombinationsKG Combination of I1/IA, I5/IE, I6/IF, and I7/IGConduit Plugs and AdaptersATEX Flamep

Seite 12 - Ambient temperature effect

2Rosemount 848T FamilyNovember 2014www.rosemount.comHigh Density Temperature MeasurementSmart Wireless delivers innovative wireless solutions for temp

Seite 13

20Rosemount 848T FamilyNovember 2014www.rosemount.comDimensional DrawingsJunction Boxes with no entries (option codes JP1, JA1, and JS1) – external di

Seite 14 - Product Certifications

21Rosemount 848T FamilyNovember 2014www.rosemount.comFigure 4. Stainless Steel Junction Box—Cable Gland (Option Code JS2)A. Ground ScrewDimensions are

Seite 15

22Rosemount 848T FamilyNovember 2014www.rosemount.comFigure 6. Stainless Steel Junction Box—Conduit Entry (Option Code JS3)A. Ground ScrewB. Five Plug

Seite 16

23Rosemount 848T FamilyNovember 2014www.rosemount.comMounting optionsFigure 7. Aluminum/Plastic Junction Box (Styles JA and JP)Dimensions are in inche

Seite 17

24Rosemount 848T FamilyNovember 2014www.rosemount.comRosemount 848T Wireless Temperature TransmitterThe Rosemount 848T is the premier choice for Wirel

Seite 18

25Rosemount 848T FamilyNovember 2014www.rosemount.comOptions (include with selected model number)Wireless burst rate, operating frequency and protocol

Seite 19

26Rosemount 848T FamilyNovember 2014www.rosemount.comWirelessHART... the Industry StandardSelf-organizing, adaptive mesh routing No wireless expertis

Seite 20 - Dimensional Drawings

27Rosemount 848T FamilyNovember 2014www.rosemount.comSpecificationsFunctional specificationsInputFour independently configurable input channels that s

Seite 21

28Rosemount 848T FamilyNovember 2014www.rosemount.comElectrical connectionsPower moduleThe Emerson SmartPower Power Module is field replaceable, featu

Seite 22

29Rosemount 848T FamilyNovember 2014www.rosemount.comAccuracy Sensor optionSensor referenceInput ranges Accuracy over range(s)°C °F °C °F2-, 3-, and 4

Seite 23 - Mounting options

3Rosemount 848T FamilyNovember 2014www.rosemount.comExperience global consistency and local support from worldwide Rosemount Temperature manufacturing

Seite 24

30Rosemount 848T FamilyNovember 2014www.rosemount.comAnalog sensors 4–20mATwo types of alarm levels are available with 4-20 mA sensors on the 848T. Th

Seite 25

31Rosemount 848T FamilyNovember 2014www.rosemount.comAmbient temperature effectTransmitters may be installed in locations where the ambient temperatur

Seite 26

32Rosemount 848T FamilyNovember 2014www.rosemount.comAmbient temperature notesExamples When using a Pt 100 (α = 0.00385) sensor input at 30 °C ambient

Seite 27 - Specifications

33Rosemount 848T FamilyNovember 2014www.rosemount.comProduct CertificationsApproved Manufacturing LocationsRosemount Inc. - Chanhassen, Minnesota, USA

Seite 28

34Rosemount 848T FamilyNovember 2014www.rosemount.comInternationalI7 IECEx Intrinsic SafetyCertificate: IECEx BAS 09.0004XStandards: IEC 60079-0:2011

Seite 29

35Rosemount 848T FamilyNovember 2014www.rosemount.comDimensional DrawingsFigure 11. Rosemount 848T WirelessDimensions are in inches (millimeters).7.0

Seite 30

Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale.The Emerson logo is a trade mark and service mark of Emerson Ele

Seite 31

4Rosemount 848T FamilyNovember 2014www.rosemount.comHigh density temperature measurementIdeal solution for taking multiple measurements in close proxi

Seite 32

5Rosemount 848T FamilyNovember 2014www.rosemount.comRosemount 848T FOUNDATION fieldbus Temperature TransmitterThe Rosemount 848T offers a low cost sol

Seite 33

6Rosemount 848T FamilyNovember 2014www.rosemount.comProduct certifications(3)Rosemount Junction Box required?NC ATEX Type n Component (Ex nA nL) No(4)

Seite 34

7Rosemount 848T FamilyNovember 2014www.rosemount.comWiringFigure 1. Rosemount 848T Sensor Wiring Diagram(1) Emerson Process Management provides 4-wire

Seite 35

8Rosemount 848T FamilyNovember 2014www.rosemount.comSpecificationsFunctional specificationsInputsEight independently configurable channels including c

Seite 36 - Product Data Sheet

9Rosemount 848T FamilyNovember 2014www.rosemount.comBackup Link Active Scheduler (LAS)The transmitter is classified as a device link master, which mea